Please click items of interest to access the information: 








 

T U R B I N E S ,   I N C .
PO Box 933
Highway 283 North
Altus, Oklahoma, 73522  USA
Phone:
1-800-809-1387
Fax: 1-580-477-3071
e-mail: karen@turbinesincorporated.com

(c) 2005-2007Turbines, Inc. all rights reserved.

Webmaster: dezi@primaryflowsignal.com

 

 

 

LIQUID TURBINE FLOW MONITOR - FM0208 -WORKHORSE

 

USE ONLY WITH 3.6v LITHIUM BATTERIES (TA0005) 

Although technology has advanced over the last decade, the FM0208 flow monitor continues to be one of the strongest selling monitors in the Turbines, Inc. line.   


Turbines, Inc. is an original equipment manufacturer located in the United States of America, specializing in the design, marketing, sales, service and manufacture of a full line of high accuracy turbine type flow meters and associated flow monitor products and accessories. 

In order to optimally realize the full performance potential of the turbine flow meter driving your flow measurement system, proper selection of the flow monitor to be used, is critical. 

Although not as feature rich as some of the higher end flow monitors that are available, the FM-0208 is the WORK HORSE of the Turbines, Inc. inventory, having thousands of successful installations to its credit, and being one of the most popular products offered by the company.

The Turbines, Inc. FM Series of flow monitors provides a rugged, durable, low cost monitor solution ideal for the demands of many field applications, including those encountered in the “Oil Patch” and numerous others needing reliable local output for instantaneous flow as well as total flow monitoring.

Please contact your Turbines, Incorporated applications group specialist for assistance in determining the best FM Series flow monitor for your particular application requirements.

The FM -0208 Series flow monitor is especially designed for providing read out for instantaneous and total flow measurements derived from the signal output of the Turbines Flow Meter product line.

This flow monitor line is intended to fully accommodate typical industrial environments as well as outdoor installations, offering a NEMA 4X
enclosure with LED read out numerals. This can be direct mounted onto the flow meter or remote mounted by use of optional cabling and
bracket arrangements.

Standard configuration for the FM-0208 Series includes battery powered operation, with optional 4-20mA output. Typical units of measure
are available in either metric or non-metric conventions, with selection being designated through mechanical DIP switch settings accessible through the
front cover plate/door of the device. Similarly, setting the calibration for the unique meter K-Factor is accomplished using the DIP switches described above.

When provided together with our turbine meter, all settings are made at the factory. Therefore, no adjustments are necessary at the point of installation.

 

 

 

 

SERIES FM TURBINES, INC. "WORKHORSE FLOW MONITOR

Turbines Part No: Description
FM0208

FLOW MONITOR-mounts directly on top of turbine flow meter and provides instantaneous flow rate indication as well as total accumulated flow . 

FM0208R

FLOW MONITOR/REMOTE MOUNT-mounts on pipe stand, wall or other location separate from the  turbine flow meter and provides instantaneous flow rate indication as well as total accumulated flow . (Includes 10 feet of cable  with straight or 90 degree connector.)

USE ONLY WITH 3.6v LITHIUM BATTERIES (TA0005) 

SERIES FM TURBINES, INC. "WORKHORSE FLOW MONITOR ACCESSORIES

Turbines Part No: Description
TA0001

REMOTE CABLE ASSEMBLY-10 foot cable assembly with straight connector. 

TA0002

REMOTE CABLE ASSEMBLY-10 foot cable assembly with 90 degree connector. 

TA0003

ADDITIONAL CABLE-additional cable  for remote mounting, available per foot. 

TA0004

STANDARD MAGNETIC PICK-UP-Magnetic pick-up for standard service (-100 degrees F to +300 degrees F.)

TA0005

BATTERY-Lithium 3.6V battery( 2 Required per monitor.)

TA0006

HIGH TEMP MAGNETIC PICK-UP-Magnetic pick-up for high temperature service (-100 degrees F to +450 degrees F.)

TA0007

HIGH TEMP CABLE ASSEMBLY-10 foot cable assembly with straight connector for high temperature service (-100 degrees F to +450 degrees F.)

TA0008

ADDITIONAL HIGH TEMP. CABLE-additional cable for high temperature remote mounting, available per foot (-100 degrees F to +450 degrees F.)

TA0009

4 - 20mA OUTPUT FEATURE-this option allows 4 - 20mA output from the FM0208.  Device is provided in separate enclosure and requires independent 12 - 24 VDC power external supply.

TA0010

0 - 5 / 0 - 10 VOLT OUTPUT FEATURE-this option provides 0 - 5 / 0 - 10 volt output from the FM0208.  Device is provided in separate enclosure and requires independent 12 - 24 VDC power external supply.

TA0011

PREAMPLIFIER-this option amplifies signal from magnetic pick-up to FM0208 flow monitor in the case of long wiring runs that may cause signal deterioration.  Device is provided in separate enclosure and requires independent 12 - 24 VDC power external supply.

 

PLEASE NOTE:

  • The equipment referenced in the above tabulation is always in stock and ready for immediate shipment.
  • All specifications are accurate at the time of publication but may change at any time without prior notice.  Please confirm performance specifications at the time of order to verify application requirements.
  • All Turbines, Inc. turbine flow meters are subjected to a three point factory calibration to establish specific k-factor of the meter. 
  • K-factors of meters are not transferable.

(c) 2005 - 2007 Turbines, Inc. - all rights reserved.
This page was last updated:
Tuesday, December 06, 2005