BCS500 Batch Controller

The BCS500 Flow Computer satisfies the instrument requirements for turbine and other pulse producing flowmeters in liquid and gas applications. Multiple flow equations and instrument functions are available in a single unit with many advanced features.

  • Supports Turbine and Other Pulse Producing Flowmeters
  • Menu Selectable Hardware & Software Features
  • RS-232 Port Standard, RS-485 Optional

Download The Manual – BCS500

 

  • Specifications
    EnvironmentalIndoor Use
    Altitude up to 2000m
    Operating Temperature: 0°C to +50°C
    (-20°C to 55°C optional)
    Storage Temperature: -40°C to +85 C
    Maximum Relative Humidity : 80% for temperatures
    up to 31°C decreasing linearly to 50% RH at
    40°C
    Mains supply voltage fluctuations not to exceed
    ±10% of the nominal voltage
    Transient overvoltage according to INSTALLATION
    CATEGORY II (see UL 3101-1 Annex J)
    POLLUTION DEGREE 2 in accordance with
    IEC 664 (see 3.7.3)
    Materials: UL, CSA, VDE approved
    Listing:CE Light Industrial,
    UL File #: E192404
    DisplayType: 2 lines of 20 characters, VFD or LCD
    Character Size: 0.3" nominal
    User selectable label descriptors and units of measure
    KeypadKeypad Type: Membrane Keypad
    Keypad Rating: Sealed to NEMA 4
    Number of keys: 16
    EnclosureSize: See Dimensions
    Depth behind panel: 6.5" including mating connector
    Type: DIN
    Materials: Plastic, UL94V-0, Flame retardant
    Bezel: Textured per matt finish
    Equipment Labels: Model, safety, and user wiring
    Power InputThe factory equipped power option is internally
    fused. An internal line to line filter capacitor is
    provided for added transient suppression.
    Order Option 1: 110VAC: 85 to 127 Vrms, 50/60 Hz
    Order Option 2: 220VAC: 170 to 276 Vrms, 50/60 Hz
    Order Option 3: 12VDC: 10.5 to 14 VDC
    Order Option 4: 24VDC: 18 to 24 VDC
    Flow Inputs:Pulse Inputs:
    Number of Flow Inputs: one
    Configurations supported: single input or
    quadrature (menu selectable)
    Input Impedance: 10 KΩ nominal
    Pullup Resistance: 10 KΩ to 5 VDC (menu
    selectable)
    Pull Down Resistance: 10 KΩ to common
    Trigger Level: (menu selectable)
    High Level Input
    Logic On: 3 to 30 VDC
    Logic Off: 0 to 1 VDC
    Low Level Input (mag pickup)
    Selectable sensitivity: 10 mV & 100 mV
    Minimum Count Speed: Selectable: 1 - 99 secs
    Maximum Count Speed: Selectable: 40, 3k, 20kHz
    Overvoltage Protection: 50 VDC
    Fast Transient: Protected to 500 VDC
    (Capacitive Clamp)
    Auxilliary/Compensation InputsThe compensation inputs are menu selectable for
    temperature, pressure, density or not used.
    Operation: Ratiometric
    Accuracy: 0.01% FS
    Thermal Drift: Less than 100 ppm/C
    Basic Measurement Resolution: 16 bit
    Update Rate: 1 update/sec minimum
    Automatic Fault detection:
    Signal Over-range/under-range
    Current Loop Broken
    RTD short
    RTD open
    Fault mode to user defined default settings
    Transient Protection: 500 V (Capacitive Clamp)
    Reverse Polarity: No ill effects
    Over-Voltage Limit (Voltage Input): 50 VDC
    Available Input Ranges
    Voltage: 0-10 VDC, 0-5 VDC, 1-5 VDC
    Current: 4-20 mA, 0-20 mA
    Resistance: 100 Ohms DIN RTD or
    Proprietary Thermistor - YSI55016
    100 Ohm DIN RTD (DIN 42-760, BS 1904):
    Three Wire Lead Compensation
    Internal RTD linearization learns ice point
    resistance
    1 mA Excitation current with reverse polarity
    protection
    Temperature Resolution: 0.01 C
    Control InputsSwitch Inputs are menu selectable for Start, Stop,
    Reset, Lock, Inhibit, Alarm Acknowledge, Print or
    Not Used.
    Control Input Specifications
    Input Scan Rate: 10 scans per second
    Logic 1: 4 - 30 VDC
    Logic 0: 0 - 0.8 VDC
    Transient Suppression: 500 V fast transient
    (Capacitive Clamp)
    Input Impedance: 100 KΩ
    Control Activation: Positive Edge or Pos. Level
    based on product definition
    Excitation Voltage110/220 VAC Powered Units
    Menu Selectable: 5, 12 or 24 VDC @ 100mA
    24 VDC Powered Units
    Menu Selectable: 5 or 12 VDC @ 100mA
    12 VDC Powered Units
    5 VDC @ 100mA
    FuseInternal self resetting fuse supplied
    Relay OutputsThe relay outputs are menu assignable to
    (Individually for each relay) Low Rate Alarm, Hi Rate
    Alarm, Prewarn Alarm, Preset Alarm, Temperature,
    Pressure, Density, Pulse Output (pulse options) or
    General purpose warning (security).
    Number of relays: 2 (4 optional)
    Contact Style: Form C contacts
    Contact Ratings: 250 VAC @ 5 amps
    30 VDC @ 5 amps
    Fast Transient Threshold: 1000 V
  • Description

    The BCS500 Flow Computer satisfies the instrument requirements for turbine and other pulse producing flowmeters in liquid and gas applications. Multiple flow equations and instrument functions are available in a single unit with many advanced features. The alphanumeric display shows measured and calculated parameters in easy to understand format. Single key direct access to measurements and display scrolling is supported.

    The versatility of the BCS500 permits a wide measure of versatility within the instrument package. The various hardware inputs and outputs can be “soft” assigned to meet a variety of common application needs. The user “soft selects” the usage of each input/output while configuring the instrument. The isolated analog output can be chosen to follow volume flow, corrected volume flow, mass flow, temperature, pressure or density by means of a menu selection. Most hardware features are assignable by this method.

    The user can assign the standard RS-232 Serial Port for data recording, transaction printing, or for connection to a computer or modem. Front panel selection of fluid type is supported. Up to 10 fluids can be stored in the unit
    Linearization options include UVC, Strouhal/Roshko and 40 point linearization tables. A Service or Test mode is provided to assist the user during start-up system check out by monitoring inputs and exercising outputs and printing system
    setup.