| Line Size | ½” to 48” Standard (special sizes available) |
| Head loss % of Differential | 30% to 70% Beta Dependent |
| Basic Accuracy (% of Total) | +/- 0.25 (Calibrated) +/- 0.50% to 0.75%, Beta Dependent (Uncalibrated) |
| Recommended pipe Reynolds number | Must be greater than 10,000, Added uncertainty under 10,000 |
| Required Straight Piping | Per ISO, AGA, ASME, API standard as applicable, 5 to 70 Pipe Diameters |
| Beta Range | 0.20 to 0.75 |
| Useful Service Life | Long, Check Periodically if Erosive Fluid is a Concern |
| Service Functional Limits | Clean liquids & gases |
| Vent or Drain Holes | Vent or drain holes are available to let trapped gas or condensate pass |
Orifice Unions are ready to install assemblies used to measure and control flow or to reduce pressure in a pipe system. They are comprised of Gaskets, Hardware and Orifice Flanges that contain pressure sensing ports. An orifice plate is also typically used with the orifice union. Once installed (welded in line), connect your dP flow transmitter and you are ready to measure flow. Configurations of this assembly are adaptable to almost any line conditions. Components that comprise the assembly can be precisely specified for any application, with carbon steel flanges and a stainless-steel orifice plate being the most common variation.
Our full-time, dedicated service group offers prompt reliable technical support services such as; evaluation, repair and recertification for flow meters including a competitor’s product. Onsite calibration services are performed by our experienced technicians proficient in using the latest test equipment.
If your application requires unique meter and instrumentation features our engineering team will design the appropriate custom equipment.
Our extensive inventory permits rapid shipment, typically within 24 hours, thus minimizing expensive down time.
ISO9001, AS9100, 3A, NIST, NTEP, CTEP, OIML R81/R117/MID, CSA, Intrinsic Safety and Canadian CRN
Turbines, Inc. serves customers worldwide with U.S. offices in Cranston, RI (headquarters); Odessa-Midland, TX; Altus, OK; Seneca, SC; and Edmonton, Alberta (Canada).
Need help finding a flow meter?
We can help guide you to the correct solution for your business needs, whether you are looking for product information, data sheets, repair information we are available to help!